This study is set up as a phase I prospective, single center, device interventional pilot study carried in office setting under local anesthesia. It will assess the tolerance and safety of target fusion ablation of prostate cancer tumors using Laser Induced Thermal Therapy (TFA-LITT) guided by fusion imaging in men 50 to 80 years of age with low to intermediate risk prostate cancerProstate Cancer is currently managed with in a discrete fashion where patients either enroll in active surveillance protocols (No intervention) or undergo full intervention via whole gland treatments - most commonly radical surgery or radiation. These treatments have not shown definitive gains in all cause survival and not uncommonly harbor undesirable adverse effects, most notably: impotency and incontinence. Such events elicit significant and noticeable changes on a male lifestyle and for most prostate cancer tumors are considered overtreatment. This study aims to evaluate the use of TFA-LITT in the office setting under local anesthesia - greatly decreasing patient perioperative surgical risk - focused on the organ sparing cancer lesion ablation, where organ function is preserved.The fundamental objective is to determine the tolerance and safety of TFA-LITT in men with low to intermediate risk prostate cancer, successful performed in the outpatient office-based setting under local anesthesia directed by fusion imaging. Secondary objectives include: 1-Biopsy proven cancer control of ablated areas 12 months after procedure; 2-Uroflowmetry and urinary function Patient Reported Outcome Measures (PROMs) at one, three, six, nine and 12 months; 3- Sexual function Patient Reported Outcome Measures (PROMs) at one, three, six, nine and 12 months; 4- MRI changes of ablated area one, three and 12 months after TFA-LITT; 5- Absence or presence of ejaculation after TFA-LITT.
Detailed Description
The field of urology currently demands better options for men diagnosed with prostate cancer, the most common solid tumor in the US and Western Europe. Recently, active surveillance has become a main alternative for patients and physicians seeking to avoid the overtreatment phenomenon associated with standard treatments. However, most men on surveillance protocols for prostate cancer end up converting to “definitive” management whether surgery or radiation within 5 years from diagnosis.
The TRANBERG®|Thermal Therapy System (Clinical Laserthermia Systems AB. Scheelevägen 2 | 223 81 Lund, Sweden), is a 25 W, 1064 nm diode laser. It uses a disposable laser applicator 14G that allows the insertion of a laser applicator (15G) with a fiberoptic core of 550µm. This thermal therapy laser system is indicated for minimal invasive ablation procedures so called Laser Induced Thermal Therapy (LITT) or also called Laser Ablation for prostate treatments. During LITT, light causes damage in tissue due to absorption of light and through heat conduction into the tissue of the absorbed energy. Light tissue interaction is reliable, reproducible, and safe. The laser fiber tip induces necrosis near the tip and coagulative effects deeper in tissues through heat conduction. The body cleans up treated tissue over time. Much experience is gained with laser ablation in different organs.
The development of medical fusion devices that incorporate the precise diagnostic findings from MRI with the flexibility of ultrasound has expanded the precision of prostate biopsies and has led thinking into the current management of prostate cancer, opening for consideration the case for partial gland ablation as an option with fewer side effects.12 Conceivably, the most promising role of fusion imaging would be in the management spectrum of prostate cancer. MRI/US fusion imaging has tremendous advantages, it delivers precise anatomical boundaries and perspectives to surgeons as they sought to destroy cancer lesions and spare healthy tissue. A better understanding on their role in ablation treatments is imperative.
The Focalyx® Fusion (Focalyx, 2140 West 68th St, #204a. Miami Lakes, FL, USA) is a novel disruptive medical device that enables an office based transperineal approach to be conducted using real-time fusion. The characteristics of this fusion device and trials studies have been well documented. This theoretically makes available a safe and laser fiber energy delivery that results in expedient and short procedure times. The Focalyx® Fusion has been used safely in the transperineal diagnosis (fusion biopsies) and management (fusion targeted cryoablation) of men with Prostate Cancer in the office setting. However, targeted prostate cryoablation carries some intrinsic disadvantages as it requires high pressure gasses. Argon and helium are not readily available worldwide, and its efficacy depends on several timely cycles demanding procedure times of about an hour or more. LITT can be accomplished in efficient minutes treatment times and can address the multi-focality of prostate cancer quite effectively. Laser ablation has proven effective when conducted in an MRI bore, however, the immensity of these machines, limited size of the bore, prone positioning and constant in and out verification makes this approach not practical. Fusion laser ablation for prostate cancer is a novel concept that can bring together the precision of MRI with the practicality of ultrasound.
The combination of the TRANBERG® laser and the FOCALYX® Fusion medical device will allow us to perform targeted transperineal fusion laser induced thermal therapy (TPF-LITT) of prostate cancer lesions. This approach portends significant advantages that the investigators can consider, among them: lesion directed ablation, sparring of critical organs and structures such as the bladder neck, NVB, urethral sphincter and rectum. Moreover, healthy tissue is spared and can perform its function, if it mirrors what the investigators have accomplished with target fusion cryoablation. It shall be expected that most men will have preservation of some ejaculation, mild changes in sexual function and no incontinence following treatment with TPF-LITT. In fact, from a urinary function status, the investigators expect patients to suffer no harm either subjectively or objectively. However, all these thoughts require rigorous evaluation. Today, there is no data or evaluation of its safety profile if/when conducted in an office setting under local anesthesia. Therefore, in this study, the principal aim is to assess tolerability and safety profile of TRANBERG® TPF-LITT conducted in men with Prostate Cancer in the office setting.
Objective: The primary objective of this study is to assess tolerability and safety, of TRANBERG® TPF-LITT in Prostate Cancer patients with clinically localized disease. The secondary objectives are to evaluate clinical performance, changes in erectile and sexual function as well as imaging volumetric changes in prostate lesions, prostate size as well as cancer control in treated areas Study design: This study is set up as open label, prospective, single center, interventional study.
Study population: Patients with low or intermediate risk prostate cancer ≥ 50 years of age.
Study Intervention: Upon meeting inclusion and exclusion criteria, subjects will undergo prostate ablation planning where the ablation areas will be noted irrespective of location so long, they are confined to this organ. The planning will allow to spare, if possible, critical structures such as the urethra, neurovascular bundles, and bladder neck. TRANBERG® TPF-LITT treatment execution will be conducted under local anesthesia using the FOCALYX® Fusion medical device as guidance for precise laser fiber localization and real-time monitoring. This investigation will employ a single fiber that will be repositioned to destroy several targeted areas to achieve the TFP-LITT goals. The surgeon will deliver the laser energy and adjust if needed. The areas treated will develop coagulative necrosis with scarring as a response to TPF-LITT. Upon conclusion of the procedure, the patient will have a multiparametric MRI of the prostate to determine the extent of ablation with this powerful technology immediately after treatment, and subsequently 1, 3 and 12 months after.
Main study parameters/endpoints: Tolerability and safety represents the main endpoints of this trial. Tolerability will be assessed during the execution of TFP-LITT. Patients will be provided with a pain analog scale and pain scores will be recorded before initiation of the procedure and during several milestones of the procedure. A final overall pain assessment will be recorded as well. Safety will be assessed during the 7-day, 30-day and 90-day clinic visits. Adverse events (AEs) will be monitored and reported using the CTCAE scale, as perioperative assessments will be conducted at each of these milestones. A grade 3 or worse AEs based on the CTCAE v5.0 within 90 days post procedure will be considered severe. Secondary outcomes will include cancer control, urinary and sexual functional outcomes. Cancer control will be measured with MRI at several milestones, serum PSA changes during the year and the definitive measure will be a Transperineal MR/US Fusion Biopsy at one year of follow up. Urinary and Sexual functional outcomes will be determined by evaluating changes in the validated questionnaires. Ejaculation will be monitored by direct questions.
The investigators aim to streamline the follow up focusing on safety according to standard of care. Patients will be instructed to contact us if they perceive any AEs. The principal investigator will oversee each patient for any AEs. Patients will be followed up in the clinic 7 days post procedure for catheter removal and AEs assessments. They will be contacted 30 days after the procedure and an AEs questionnaire will be administered as well. AEs, IPSS and SHIM assessments will be done at the 6 weeks and 3-month visits. IPSS and SHIM assessments will be done at the 6-month, 9-months and 12-months visits. Flow and volumetric studies will be conducted 3 months and 12 months from procedure date. From an oncological perspective, patients will have serum markers evaluations – PSA, Testosterone Creatinine and GFR measurements prior to a multiparametric MRI and subsequently before each MRI at months 1, 3 and 12 after TPF-LITT procedure. Critically, the Focalyx® Fusion device will be used to assess the delta changes for each lesion and overall change in prostate configuration after each MRI performed. This will allow further understanding of the speed of tissue retraction, remodeling, and spatial orientation of the treated areas for each patient. Finally at 12 months, a MR/US Transperineal fusion biopsy will be performed to assess the ablated tissue cancer sterility.
In Conclusion, TRANBERG® TPF-LITT will expose patients to potential intervention risks. However, it is our estimation and bias these potential risks will be favorable or equal to those observed with compared available standard minimal invasive treatment approaches such as active surveillance. The risks usually associated with transrectal procedures is eliminated as all treatments will performed via a transperineal access. The burden is in our opinion favorable and acceptable.
Locations
1 location Found with status Recruiting
Status
- RECRUITING
Contact Person
- Isabel H Lopez, MS, MBA
- 786-431-2014
- [email protected]
Principal Investigator
- Fernando J Bianco, MD
Eligibility Criteria
Inclusion Criteria:
* Willing and able to sign informed consent
* Subject is able and willing to complete all procedure and follow-up visits indicated in the protocol
* Absence of urinary retention
* Prostate volume: ≥ 18 and ≤ 100 cc, measured by transrectal ultrasound
* Serum creatinine levels <2 ng/dl and GFR > 45
* Serum PSA levels < 20 ng/ml
* Multiparametric prostate MRI with piRADS scores 3-5
* Prostate volume: ≥ 18 and ≤ 100 cc, measured by MRI
* Presence of Intermediate risk prostate cancer with a volume that is less than 1/3 of the gland volume by MRI evaluation
Exclusion Criteria:
* Post-void residual (PVR): > 250 mL or > 50% of voided volume
* Previous prostate cancer intervention (Radiation therapy, brachytherapy, prostate cryoablation
* Major neurological conditions such as Alzheimer's, Parkinson, Multiple sclerosis, ALS, spinal cord injury
* Evidence of neurogenic bladder determined by urodynamics studies
* Presence of Indwelling Foley catheter or on active regime of clean intermittent catheterization (CIC) in the prior 30 days
* Active urinary tract infection determined by urinary cultures
* SHIM score <14
* IPSS score >23
* Acute prostatitis
* Macroscopic hematuria without a known contributing factor
* History of colorectal carcinoma with anterior perineal resection of rectum
* History of pelvic radiation therapy or radical pelvic surgery
* History of bladder neck contracture and/or urethral strictures within the 5 years prior to the informed consent date
* Bladder stones
* Medical contraindication for undergoing TPFLA surgery (eg, infection, coagulopathy, significant cardiac or other medical risk factors for surgery)
* Diagnosed or suspected bleeding or coagulopathic disorder such as hemophilia, ITP, TTP
* Medical contraindication to being subjected to local anesthesia
Study Plan
TPF-LITT ARM
EXPERIMENTAL
partial gland ablation of the prostate using laser device and imaging fusion
DEVICE:
TRANBERGu00ae Transperineal Fusion Laser--Induced Thermal Therapy of Prostate Cancer (TPF-LITT)Description:
A perineal local anesthesia block is performed with patient on lithotomy. The ultrasound probe is advanced, secured to digital stepper. The live ultrasound image feed is visible on the FOCALYXu00ae Fusion device. Image co-registration (MR/US) will be performed. The FOCALYXu00ae Fusion device shows outline of the prostate on the MRI and the target area(s) in real-time. The urologist advances laser fiber introducer, temperature probes to indicated coordinates. Target treatment - applying TRANBERGu00ae laser energy over the treatment area and controlling delivery with a pedal. Treatment is monitored using FOCALYXu00ae Fusion device in real-time. One laser fiber will be used and a single or multiple applications may be required. The fiber will be relocated to other targets if present. Patient will be dismissed to the MRI center where a multiparametric MRI will be conducted. After this study is completed, the patient will be discharged home with instructions and contact information.
Outcome Measures
Primary Outcome Measures
Incidence of Treatment-Emergent Adverse Events [Safety and Tolerability] of TRANBERGu00ae TPF-LITT performed in the office setting under local anesthesia.
Secondary Outcome Measures
Average Ablated area volume (in cc) measured by MRI immediately following the procedure
Average Ablated area volume (in cc) measured by MRI 1-month following the procedure
Average Ablated area volume (in cc) measured by MRI 3-month following the procedure
Average Ablated area volume (in cc) measured by MRI 1-year following the procedure
Number of patients with a 75% decrease in Serum PSA levels (ng/ml) after procedure measured at fixed intervals
Number of patients with presence of cancer cells in treated -ablated- area
Number of patients with a 50% increase in qMAX measured in cc/second on flow studies
Number of patients with a 7 point drop in the International Prostate Symptom Score (IPSS)
Number of patients with a 5 point drop in the sexual health inventory for men (SHIM) scores
Number of men with absent ejaculation
Timeline
Last Updated
January 26, 2023Start Date
January 26, 2023Today
January 16, 2025Completion Date ( Estimated )
January 30, 2033
Sponsors of this trial
Lead Sponsor
Urological Research Network, LLC